Occupancy & Load
Sent. 3.7.2.2.(9) At least one water closet shall be provided for each dwelling unit.
Sent. 3.7.2.2.(7) For detention and treatment occupancies, the number of water closets shall be determined on the basis of the special needs of the occupancy. Consult with the operator.
Occupant load determined per Subsection 3.1.17.
Male
Female
Each sex rounded up to the nearest whole person — e.g. 101 total = 51M, 51F. Override if actual proportion is known per Sent. 3.7.2.2.(1)
Single Water Closet Permitted — Occupant load is 10 or fewer. Both sexes may be served by one water closet per Sent. 3.7.2.2.(2).
Urinals (Male)
0
Unisex WC
0
Urinals substitute up to ⅔ of required male WC. Unisex WC substitute for the sex with the remaining deficit, up to the deficit amount.
Applicable Exemptions
Enter occupancy details and click Calculate to determine plumbing fixture requirements.